Products

  • Filter
  Name SKU Description Category
Fluke 3300 Clamp-on Current Transformer Current range: 10-3000A Accuracy: 2% RDG +/- 0.05% FS Frequency response: 5 kHz Jaw opening: 3.5 x 4.5” dia. (9 x 11 cm) Current Clamp DMM Accys
Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe, 2 Feet Long For the Fluke 1750 Power Recorder The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe  is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. Current Clamp DMM Accys
Fluke 3212-PR-TF 5000A Flex Thin Flex Current Probe, 4 Feet Long For the Fluke 1750 Power Recorder The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe  is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. Current Clamp DMM Accys
Fluke 3583R Split-Core Current Transformers Current range: 0.01 – 10A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamp DMM Accys
Fluke 3584R Split-Core Current Transformers Current range: 0.1 – 40A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamp DMM Accys
Fluke 3585R Split-Core Current Transformers Current range: 0.5 – 1-0A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamp DMM Accys
Fluke TPS CLAMP 10 A / 1 A Clip-on Current Transformer Measuring Range selectable per software:0.01A to 1A0.1A to 10A Peak current for sinusoidal currents:3.7A to 37A Intrinsic error: 0.5% Frequency Range: 40Hz to 10kHz Operating Voltage: 300V CAT IV Phase Error: 0.5° Jaw Opening: <15mm diameter or 15x17mm bus bars Errors in % of measuring range at 23°C ± 2K; 74°F±2K, for 48 to 65Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS CLAMP 200 A / 20 A Clip-on Current Transformer Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A Peak current for sinusoidal currents74 A 300 A Intrinsic error 0.5% Frequency Range 40 Hz to 10 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS CLAMP 50 A / 5 A Clip-on Current Transformer Measuring Range selectable per software 1 A to 100 A 5 A to 500 A Peak current for sinusoidal currents 240 A 1350 A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening 45 cm length 2 m cable Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS FLEX 18-TF 100A/500A Thin Flex Flexible Current Probe with 18-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 1A to 100A 5A to 500A Peak current for sinusoidal currents: 240A 1350A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS FLEX 24-TF 200A/1000A Thin Flex Flexible Current Probe with 24-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 2A to 200A 10A to 1000A Peak current for sinusoidal currents: 480A 2700A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 600 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS FLEX 36-TF 3000A/6000A Thin Flex Flexible Current Probe with 36-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 30A to 3000A 60A to 6000A Peak current for sinusoidal currents: 10kA 19kA Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke 373 True-RMS 600A/600V AC Clamp Meters 600 A ac current measurement with fixed jaw 600 V ac and dc voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals Resistance measurement to 6000Ω with continuity detection 1000 µF capacitance measurement State of the art signal processing allows for use in noisy electrical environments while providing stable readings Large, easy to read, backlight display automatically sets the correct measurement range so you do not need to change switch... Current Clamp Meters
Fluke 365 True-rms AC Clamp Meter with Detachable 18mm Jaw 200A ac and dc current measurement with detach-able jaw 600V ac and dc voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals 6000Ω resistance measurement with continuity detection Detachable jaw makes accessing wires and viewing the display easier Built in flashlight/torch allows for easy illumination and identification of wires CAT III 600V safety rating Compact design fits in your hand and can be used while wearing personal protective... Current Clamp Meters
Fluke 323 400A AC, 600V AC/DC True-RMS Clamp Meter 400 A AC current measurement 600 V AC & DC voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals Resistance measurement up to 40 kΩ with continuity detection Features: Slim, ergonomic design CAT IV 300V/CAT III 600 V safety rating Hold button Two-year warranty Soft carrying case Current Clamp Meters
Fluke 324 40/400A AC, 600V AC/DC True-RMS Clamp Meter with Temperature, & Capacitance Measurements 400 A AC current measurement 600 V AC & DC voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals Resistance measurement up to 40 kΩ with continuity detection Temperature and capacitance measurement Features: Slim, ergonomic design Backlight display CAT IV 300V/CAT III 600 V safety rating Hold button Two-year warranty Soft carrying case Current Clamp Meters
Fluke 325 40/400A AC/DC, 600V AC/DC True-RMS Clamp Meter with Frequency, Temperature, & Capacitance Measurements 400 A ac and dc current measurement 600 V ac and dc voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals Resistance measurement up to 40 kΩ with continuity detection Temperature and capacitance measurement Frequency measurement Min/Max functionality Features: Slim, ergonomic design Backlight display CAT IV 300V/CAT III 600 V safety rating Hold button Two-year warranty Soft carrying case Current Clamp Meters
Fluke 353 AC/DC TRMS 2000 A Clamp Meter; Amps Only For Voltage Measurements, See : Fluke 355 Clamp Meters Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc The large 58 mm (2.3 in) jaw capacity is suitable for large, or multiple conductors CAT IV 600 V, CAT III 1000 V rating for added user protection In-rush current measurement captures 'power-on' surge current with accuracy and repeatability Accurately measure frequency up to 1 kHz for optimum troubleshooting Quickly analyze readings using the MIN, MAX, and AVG functions A... Current Clamp Meters
Fluke 355 AC/DC TRMS 2000 A Clamp Meter See Also: Fluke 353 Clamp meter Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc The large 58 mm (2.3 in) jaw capacity is suitable for large, or multiple conductors CAT IV 600 V, CAT III 1000 V rating for added user protection In-rush current measurement captures 'power-on' surge current with accuracy and repeatability Accurately measure frequency up to 1 kHz for optimum troubleshooting Quickly analyze readings using the MIN, MAX, and AVG functions A... Current Clamp Meters
Fluke 374 600A/600V True-RMS AC/DC Clamp Meter 600A AC and DC current measurement with fixed jaw 2500 A ac current measurement with iFlex flexible current probe (sold separately) 600 V ac and dc voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals Resistance measurement of 6000 Ω with continuity detection Min, max, average and inrush recording to capture variations automatically 500 mV dc measurement range to interface with other CAT IV 600V, CAT III 1000 V safety rating iFlex... Current Clamp Meters